RoTeK-swt-BT-BT-6709-signals-MIB DEFINITIONS ::= BEGIN IMPORTS enterprises, NOTIFICATION-TYPE, OBJECT-TYPE, MODULE-IDENTITY, Integer32 FROM SNMPv2-SMI; rotek MODULE-IDENTITY LAST-UPDATED "202205300000Z" ORGANIZATION "Rotek" CONTACT-INFO " Rotek Customer Support E-mail: support@rotek.ru" DESCRIPTION "BT-6709-MTS" REVISION "202205300000Z" DESCRIPTION "" ::= { enterprises 41752 } swt OBJECT IDENTIFIER ::= { rotek 911 } bt-6709-mts OBJECT IDENTIFIER ::= { swt 8 } signals OBJECT IDENTIFIER ::= { bt-6709-mts 1 } traps OBJECT IDENTIFIER ::= { bt-6709-mts 2 } fwVersion OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "FWVersion" ::= { signals 1 } restoreSignal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Restore settings 1 - restore settings" ::= { signals 2 } rebootSignal OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Reboot device: 1 - reboot" ::= { signals 3 } upsModel OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "UPS model" ::= { signals 4 } upsSerial OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "UPS serial" ::= { signals 5 } upsVersion OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "UPS version" ::= { signals 6 } batTest OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "0 - cancel test 1-99 - run test to x minutes 100 - run test to 10 seconds 999 - test till charging" ::= { signals 7 } shutdown OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Control of shut down UPS load: 0 - stop shut down load n - shut down load in n minutes n: 0.2, 0.3, .., 1, 2, .., 10" ::= { signals 8 } intTemp OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Internal temperature" ::= { signals 9 } inFreq OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Input frequency, Hz" ::= { signals 10 } inVoltVAC OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Input voltage" ::= { signals 11 } outVoltVAC OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Output voltage" ::= { signals 12 } power OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Power, %" ::= { signals 13 } batCap OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Battery capacity, %" ::= { signals 14 } batTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Rest working time of battery, min" ::= { signals 15 } connectMonitor OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Connect status: 0 - normal; 1 - connect fail" ::= { signals 16 } alarms OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "bit 7 - utility fail bit 6 - battery low bit 5 - bypass/boost or buck active bit 4 - UPS fail bit 3 - UPS Type is Standby (0 is On_line) bit 2 - Test in Progress bit 1 - Shutdown Active bit 0 - Beeper On" ::= { signals 17 } server1 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Get/set server1 for traps" ::= { signals 18 } server2 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Get/set server2 for traps" ::= { signals 19 } server3 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Get/set server3 for traps" ::= { signals 20 } server4 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Get/set server4 for traps" ::= { signals 21 } server5 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Get/set server5 for traps" ::= { signals 22 } whiteListRange1 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "white List Range1" ::= { signals 23 } whiteListRange2 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "white List Range2" ::= { signals 24 } whiteListRange3 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "white List Range3" ::= { signals 25 } whiteListRange4 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "white List Range4" ::= { signals 26 } whiteListRange5 OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "white List Range5" ::= { signals 27 } upsVoltCellMin OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "UPS voltage cell min" ::= { signals 28 } upsVoltCellMax OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "UPS voltage cell max" ::= { signals 29 } vacAlarmHighRange OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "VAC alarm high range" ::= { signals 30 } vacAlarmLowRange OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "VAC alarm low range" ::= { signals 31 } vacAlarmHistRange OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "VAC alarm hist range" ::= { signals 32 } tempAlarmHighRange OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Temperature alarm high range" ::= { signals 33 } tempAlarmLowRange OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Temprature alarm low range" ::= { signals 34 } tempAlarmHistRange OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Temprature alarm hist range" ::= { signals 35 } loadAlarmHighRange OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Load alarm high range" ::= { signals 36 } loadAlarmHistRange OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-write STATUS current DESCRIPTION "Load alarm hist range" ::= { signals 37 } sntpTimeZone OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Sntp time zone" ::= { signals 38 } sntpState OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "SNTP synchronization state 0 - disable 1 - enable" ::= { signals 39 } sntpServerIp OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Sntp server IP address" ::= { signals 40 } sntpLastData OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "SNTP last synchronization timestamp" ::= { signals 41 } dateController OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Current date, YYYY-MM-DD" ::= { signals 42 } timeController OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-write STATUS current DESCRIPTION "Current time, hh:mm" ::= { signals 43 } akbWorkTime OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "Work time from AKB, minutes" ::= { signals 44 } currInput OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "UPS input current, A" ::= { signals 45 } currOutput OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "UPS output current, A" ::= { signals 46 } voltAKB OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "AKB current voltage, V" ::= { signals 47 } normCapacityAKB OBJECT-TYPE SYNTAX Integer32 MAX-ACCESS read-only STATUS current DESCRIPTION "AKB normal capacity, Ah" ::= { signals 48 } changeDataAKB OBJECT-TYPE SYNTAX OCTET STRING MAX-ACCESS read-only STATUS current DESCRIPTION "Data of change AKB" ::= { signals 49 } -- DEVICE TRAPS fwVersionUpdate NOTIFICATION-TYPE OBJECTS { fwVersion } STATUS current DESCRIPTION "" ::= { traps 1 } fwVersionUpdated NOTIFICATION-TYPE OBJECTS { fwVersion } STATUS current DESCRIPTION "" ::= { traps 2 } deviceRestored NOTIFICATION-TYPE OBJECTS { restoreSignal } STATUS current DESCRIPTION "" ::= { traps 3 } deviceRebooted NOTIFICATION-TYPE OBJECTS { rebootSignal } STATUS current DESCRIPTION "" ::= { traps 4 } batteryTemperatureHighNorm NOTIFICATION-TYPE OBJECTS { intTemp } STATUS current DESCRIPTION "" ::= { traps 5 } batteryTemperatureHighAlarm NOTIFICATION-TYPE OBJECTS { intTemp } STATUS current DESCRIPTION "" ::= { traps 6 } lineAlarm NOTIFICATION-TYPE OBJECTS { inVoltVAC } STATUS current DESCRIPTION "" ::= { traps 7 } lineNorm NOTIFICATION-TYPE OBJECTS { inVoltVAC } STATUS current DESCRIPTION "" ::= { traps 8 } lowBatAlarm NOTIFICATION-TYPE OBJECTS { batCap } STATUS current DESCRIPTION "" ::= { traps 9 } lowBatNorm NOTIFICATION-TYPE OBJECTS { batCap } STATUS current DESCRIPTION "" ::= { traps 10 } powerAlarm NOTIFICATION-TYPE OBJECTS { power } STATUS current DESCRIPTION "" ::= { traps 11 } powerNorm NOTIFICATION-TYPE OBJECTS { power } STATUS current DESCRIPTION "" ::= { traps 12 } connectMonitorAlarm NOTIFICATION-TYPE OBJECTS { connectMonitor } STATUS current DESCRIPTION "" ::= { traps 13 } connectMonitorNorm NOTIFICATION-TYPE OBJECTS { connectMonitor } STATUS current DESCRIPTION "" ::= { traps 14 } batteryConnectAlarm NOTIFICATION-TYPE OBJECTS { batCap } STATUS current DESCRIPTION "" ::= { traps 15 } batteryConnectNorm NOTIFICATION-TYPE OBJECTS { batCap } STATUS current DESCRIPTION "" ::= { traps 16 } batteryTemperatureLowNorm NOTIFICATION-TYPE OBJECTS { intTemp } STATUS current DESCRIPTION "" ::= { traps 17 } batteryTemperatureLowAlarm NOTIFICATION-TYPE OBJECTS { intTemp } STATUS current DESCRIPTION "" ::= { traps 18 } changeBatteryAlarm NOTIFICATION-TYPE OBJECTS { intTemp } STATUS current DESCRIPTION "" ::= { traps 19 } changeBatteryNorm NOTIFICATION-TYPE OBJECTS { intTemp } STATUS current DESCRIPTION "" ::= { traps 20 } END